Hi! I'm looking for advice. I'm using TrustedLink for Windows and STMAP. So far, I've only used STMAP for purchase orders and invoices and I've had help with...
I like STMap quite a bit. I can't see how powermapper could do the UCC128's where STMap cannot. What's the advantage of powermapper? Dan ... From: "IC777"...
Dan, The rep was pushing the graphical interface where you have two columns of fields. Select one from column A and one from column B and create a link. I have...
I see... the graphical interface... well, I dunno how much of an advantage that is. I can see it being a (slight) advantage only if you don't know how to map...
UCC128s are generated in the software we use to print the barcode labels. The software isn't very sophisticated. All I can get out of it is a summary report....
Is your barcode software integrated with your ERP software in any way? Curtis ... From: Ian Cochrane [mailto:ic777@...] Sent: Thursday, October 17, 2002...
Curtis Evans
evansc@...
Oct 17, 2002 2:18 pm
422
My experience with PowerMapper was a very poor one. I wanted to use it to allow mapping from a 'real' database such as Access or SQL, etc instead of comma...
Thanks, Brian. This is helpful. ... __________________________________________________ Do you Yahoo!? Faith Hill - Exclusive Performances, Videos & More ...
No, it isn't. I wish it was. Ian ... __________________________________________________ Do you Yahoo!? Faith Hill - Exclusive Performances, Videos & More ...
No, you're ok, but STMap is capable of making a map reading from 2 files. If your Excel is in a list, you can set a counter in STMap that doesn't clear ...
Brian pretty well put it in a "nut shell". ... From: Ian Cochrane [mailto:ic777@...] Sent: Thursday, October 17, 2002 9:27 AM To: stmap@yahoogroups.com ...
Curtis Evans
evansc@...
Oct 17, 2002 2:39 pm
427
Thanks, Dan. Ian ... === message truncated === __________________________________________________ Do you Yahoo!? Faith Hill - Exclusive Performances, Videos &...
Hi everyone. Looking for some insight to a dreaded STMAP looping problem. The transaction set is an 870. I will attempt to show my loop structure and also...
Don't you have it reading on the I/O rule for the detail level? In other words, is the data for the PID's and MEA's in the same record as the PO1? What does...
The data for the PO1 is in 1 file. Data for the PID in another, and data for the MEA file is in another. The idea is to have the EDI look like this: PO1 PID ...
Who has this position, are you looking for a contractor/consultant ... From: Ian Cochrane [mailto:ic777@...] Sent: Thursday, October 17, 2002 1:21 PM ...
Hamid Ahmad
hsahmad@...
Oct 17, 2002 8:40 pm
435
Sorry to be such a tease, but the recruiter changed her mind about posting the information here. I received an email, asking if I knew anyone who would be...
Brian, Send me the map file I will be able to help you Hamid ... From: Brian J. Eckenrod [mailto:beckenrod@...] Sent: Thursday, October 17, 2002...
Hamid Ahmad
hsahmad@...
Oct 17, 2002 8:44 pm
437
ahhh... now I understand what you are doing... ouch :) I try to stay away from match and breaks for this very reason - it's tough to make it work right. Now, I...
I would assume so. I know Dan does STmap consulting and I work for a consulting company as well. I am sure there are others subscribed here that do as well. ...
Well, I have also tried to get it to work using pregenerated key fields "+", with similar success (or lack thereof). This data is in 3 different files, yes....
May I ask how it knows to stop reading the PID file and start reading MEA's? The setting up the Mea as a child seems to start you on the right track at least. ...
That is a good question. I would assume that the map should read the PID or MEA file until it's match field differs from the break field of it's parent. Then...
But where are you putting the break fields? From your data that I saw, it seems it's in the beginning of the record? I would think it needs to be at the end of...
Well, if I understand the mapping process, I think this is how it would work. The file that feeds the PO1 segment has BREAK fields that look like this: Record...
Keep in mind it's been awhile since I've had to use a match or break or anything, but isn't the match field primarily used with the key field to let it know...